Kushandiswa kwedata Center uye UPS
Data Center Overview:
Nzvimbo dzeData dzinodyidzana pasi rose dzakanangana netiweki yemidziyo inoshandiswa muIntraTransfer, mhanyisa, ratidza, kuverenga, uye kuchengeta data neruzivo pane network network. Mazhinji emagetsi munzvimbo yedata anofambiswa neakaderera-DC magetsi emagetsi.
Kubuda kwenzvimbo dzedata kwaita kuti vanhu vanzwisise kubva kune yakawandisa uye yakarongeka nyika kuenda kune isina chokwadi uye isina kurongeka nyika. Zvishoma nezvishoma zvichave chikamu chezvivakwa zvevanhu vemazuva ano, sekufambisa uye kutaurirana kwenetiweki, uye zvobva zvave nemhedzisiro yakanaka kune akawanda maindasitiri. Zvisinei, kukurudzirwa kwenzvimbo dze data hakufaniri kungovimba nezvakaitika, asiwo kunyatsobatanidza nekudzidzira kusimudzira nzvimbo dze data kuti dziite basa rinokosha uye rinokurudzira kukurumidza kuchinja kwevanhu.


A Schematic diagram yeUPS system
- simba risingapindikiUPS isimba risingapindiki, iro ririsimba risingapindiki rine magetsi ekuchengetedza magetsi. Inonyanya kushandiswa kupa simba risina kukanganiswa kune vamwemidziyo ine zvakakwirira zvinodiwa pamagetsi ekupa kugadzikana zvinodiwa.
- kushanda musimbotiKana iyo mains simba rekuisa yakajairika, iyo UPS inopa iyo mains simba mushure mekudzikamisa kwevoltageKutakura kushandiswa, iyo UPS panguva ino ndeye AC ikozvinoMutongi anochajawo bhatiri; apo simba guru rinokanganiswa (accident outage), iyo UPS pakarepo inopfuura yakananga ikozvino yebhateriNzira ye inverter switching uye kushandura inoramba ichipa 220V kana 380V kune loadAC kuchengetedza mutoro uchishanda uye kuchengetedza mutoro unyoroI hardware haina kukuvara.UPSEquipment inowanzopa dziviriro kune yakakwirira kana yakaderera voltage.
- ShandisaMunzvimbo yedata, iyo yakafanana redundant UPS sisitimu inoumbwa neaviri shanduko UPS imwechete unit inowanzoshandiswa. Kana iyo datapakati mutoro ndeye mbiri mbiri magetsi, iyo yakafanana redundant UPS inoshandiswa kugadzira maviri bhazi UPS magetsi ekupa system.
Zvimiro zve lithium bhatiri UPS
Iyo lithium bhatiri UPS system, yakasanganiswa nehunhu hwehurefu hwesimba, diki tsoka, hupenyu hurefu hwebasa, kuchengetedzwa kwepamusoro, kushanda kuri nyore uye maitiro ekugadzirisa, inogona kupa yakakwira mhando simba vimbiso yenzvimbo yedata, IT room uye mikuru mikuru mikuru muminda yekutaurirana, IT uye maindasitiri minda.


- mabasa ekudziviriraIyo yekuchaja uye yekuburitsa kutenderera nguva inogona kusvika 5000 nguva, uye hupenyu hwesevhisi hunogona kusvika makore gumi. Iyo BMS bhatiri manejimendi system ine yakakwana kuchengetedza mabasa (pfupi dunhu, overcurrent, overcharge, overdischarge, overtemperature, etc.)
- kudzivirira kutongaLithium UPS system ine matatu-nhanho yekudzivirira yekudzora, UPS uye BMS inoziva iyo yese yekutarisa maviri maviri lithium bhatiri backup system.
- dhizaini yakarongekaPACK module yakamisikidzwa dhizaini inogona kusanganiswa zvakasununguka, uye vhoriyamu uye huremu ndeye 1/3 yelead-asidi bhatiri, iyo inonyanya kukodzera kune spatially shoma application mamiriro.

parameter list
3Y3T3R00 | 3YST4R00 | 33Y5T0RO3 | 3Y3T6R00 | 3Y3T8R00 | 33Y1T0R | 33Y1T2R00 | ||
UPS | Input voltage range (Vac) | 228~477 | ||||||
Input frequency range (Hz) | 50 / 60 ± 10% (± 5 sarudzo) | |||||||
Input Current | Yakazara mutoro weTHDi 2% | |||||||
Harmonics (THDi) | ||||||||
Output power factor | Kusvika ku1.0 | |||||||
Output voltage (Vac) | 380 ± 1% (400 ± 1%, 415 ± 1% sarudzo) | |||||||
Output (wave TH chimiro D yakarasika v) chokwadi | ||||||||
overload capacity | Mutoro 105%: kushanda kwenguva refu; 105% | |||||||
pfuura mushure me1min | ||||||||
zvakazara | Kusvika 97% | |||||||
kunyatsoshanda | ||||||||
kuchaja ikozvino (A) | 25~100 | 25~200 | ||||||
PANE | Tsigira RS232 / 485, MODBUS, yakaoma kuonana kutaurirana (SNMP inosarudzwa) | |||||||
kushanda tembiricha (℃) | -5~40 | |||||||
hunyoro hwehukama | 0 ~ 95%, pasina condensation | |||||||
(Yakafara, tsoka, yakadzika, inch, kureba) | 1000×900×1950 | 1400×900×1950 | 1900×900×1950 | 3000×900×1950 | ||||
(mm) | ||||||||
uremu (kg) | 700 | 1100 | 1300 | 2400 | ||||
lith ium cell | System nominal voltage (Vdc) | 512 | ||||||
Modhi nominal voltage (Vdc) | 51.2 | |||||||
Muenzaniso wezita simba (Ah) | 50/100/200 | |||||||
System Voltage Range (Vdc) | 448~584 | |||||||
Sero (Ah) | 50/100/200 | |||||||
kuchaja ikozvino (A) | ≤1C | |||||||
kubuda ikozvino (A) | 4C/1C | |||||||
heat management | kumanikidzirwa kutonhora kwemhepo | |||||||
Mode uremu (kg) | 35/70/80 | |||||||
(Wide module kudzika mutongi inch kureba) (mm) | 442×690×106/442×800×150/442×810×127 | |||||||
(Wide pool yakadzika kabati kureba) (mm) | 600×800×2000/600×1000×2000 |


Zvimiro zve lithium bhatiri UPS
Kuwedzera kune data center lithium UPS, kune akawanda anowanzoyakashandiswa backup, online UPS, inonyanya kushandiswa muhurumende, dzidzo, mari, kutaurirana, inishuwarenzi, chekufambisa, mutero, kuchengetedzwa, nezvimwe.
minda.
Lead-asidhi mabhatiri mumashandisi ekuchengetedza simba achiri kunyanya kushandiswa munzvimbo idzi
Matatu mune imwe chete akatevedzana matatu mune matatu kunze akateedzana parameter runyorwa
? | YTR3320 | YTR3330 | YTR3340 | |
kukosha t chara cteri stic | Simba rekupa system | 3W+N+PE | ||
Input voltage range (Vac) | LN:80~275 | |||
Input frequency range (Hz) | 40~70 | |||
Bypass input voltage range (Vac) | ± 20%, ± 15%, ± 10% inogona kusetwa (default ± 20%) | |||
Input simba factor | >0.99 | |||
Input current harmonics | ||||
sero (Vdc) | ± 144- ± 240 Inochinjika (default: ± 192) | |||
outpu t chara cteri stic | Output power factor | 1.0 | ||
voltage (Vac) | LN: 220 / 230 / 240 ± 1% (default 220) | |||
frequency (Hz) | mains akajairika, tracking bypass input; mains abnormal, emunharaunda 50 ± 0.1 kana 60 ± 0.1 | |||
Wwaveform kukanganisa (THD v) | ||||
kunyatsoshanda | Kusvika 96% | |||
overload capacity | Mutoro 105%: kushanda kwenguva refu; 105% 155% | |||
zvimwe charac terist ic | DC kutanga basa | possess | ||
Kukurukurirana basa | Yakajairwa RS485,1 yekuisa yakaoma kubata uye 3 inobuda yakaoma kubata | |||
Yambiro basa | Input abnormality, bhatiri yakaderera voltage, kuwandisa, kukanganisa, nezvimwe | |||
kudzivirira basa | Kubuda kwedziviriro yedunhu pfupi, kuburitsa overvoltage / undervoltage dziviriro, kuwedzeredza kuchengetedza, pamusoro pekudzivirira tembiricha, bhatiri undervoltage dziviriro, nezvimwe. | |||
kushanda tembiricha | 0~40℃ |